| Customization: | Available |
|---|---|
| Type: | Horizontal Fiber Optical Splice Closure |
| Wiring Devices: | ODF |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
| TGJS104 Fiber Optical Splice Box | |
| Material | 100% NEW PC(Polycarbonate) Fiber Optic Splitter Splice Closure |
| Size | 525*200*130mm Fiber Optic Splitter Splice Closure |
| Cable Ports | 2 In / 2 Out |
| Max Capacity | 144FO Fiber Optic Splitter Splice Closure |
| Splice Tray | 12/ 24FO*6 Fiber Optic Splitter Splice Closure |
| Weight | 4.5KG Fiber Optic Splitter Splice Closure |
| Accessories | Protecting Sleeves, labelling paper, insulation tape, abrasive paper, wall-mount kits, sealing tape, nylon tie, earthing wire, plastic wrench |
| Sealing Way | Silicon Rubbersealing Ring Fiber Optic Splitter Splice Closure |
| Installation Way | Aerial, wall or pole-Mounting Fiber Optic Splitter Splice Closu |
| Characteristics | Value/Performance | Methods and Conditions |
| Mechanical | ||
Air Tightness |
No air bubble seen | Put closure under water for 15min with closure's internal air pressure set at 100kPa±5kPa. |
| Remains100kPa±5kPa | Measure the internal pressure 24 hours later | |
Air Tightness after re-installation |
No air bubble seen and pressure remains unchanged | Do re-entry and re-installation 3 times and repeat above Air Tightness Tests. |
Axial Pulling |
Pressure remains unchanged |
Pulling force: 1000N Time: 1min Internal air pressure: 60kPa±5kPa |
Compression |
Pressure remains unchanged |
Applied pressure: 2000N/100mm Time: 1min Internal air pressure: 60kPa±5kPa |
Impact |
Pressure remains unchanged |
Impact energy: 16N.m No. of impacts: 3 Internal air pressure: 60±5kPa |
Bending |
Pressure remains unchanged |
Bending angle±45°(in two opposite directions) Tension: 150N No. of bending: 10 Internal air pressure: 60kPa±5kPa |
Twisting |
Pressure remains unchanged |
Twisting angle: ±90° Torque: 50N No. of twisting: 10 Internal air pressure: 60kPa±5kPa |
| Thermal | ||
Temperature Cycling |
Pressure drop ≤5kPa |
Cycling range: -40 ~ +60°C Cycling time: 2hrs at -40°C, then 2hrs at +60°C No. of cycling: 3 Internal air pressure: 60kPa±5kPa |
| Electrical | ||
Insulation |
Resistance between metal parts:2.0x105MΩ |
Soak closure into water in 1.5m-depth for 24hrs, and measure the insulation resistance after taking it out of water. |
| Resistance between each metal part and ground:2.0x105MΩ | ||
High Voltage |
No voltage break-downs and sparks Fiber Optic Splitter Splice Closure |
Soak closure into water in 1.5m-depth for 24hrs, then apply 15kV DC to the metal parts inside |